Pensky-Martens Closed-Cup Flash Point Tester SYD-261-1

  • Pensky-Martens Closed-Cup Flash Point Tester SYD-261-1
  • Pensky-Martens Closed-Cup Flash Point Tester SYD-261-1
  • Pensky-Martens Closed-Cup Flash Point Tester SYD-261-1
  • Pensky-Martens Closed-Cup Flash Point Tester SYD-261-1
  • Pensky-Martens Closed-Cup Flash Point Tester SYD-261-1
Pensky-Martens Closed-Cup Flash Point Tester SYD-261-1

Summary
This instrument is designed and manufactured as per standards GB/T 261-2021 Determination of Flash Point - Pensky-Martens closed cup method and ASTM D93 Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester. It is used to make determination of the closed cup flash point of the petroleum products.

I. Main technical features

1. Single chip microcomputer control technique.LCD screen displays.English man-machine interaction interface.The heating power is continuously step-less adjustable.The rate of heating up is exact.Easy setting for parameters.

2. The LCD screen has prompting menu,prompting input operation interface.It shows the setted parameters,real-time temperatures and other test parameters.Press the “record”button when the flash point appears.The screen will show and reserve the flash point.

3. The structure is newly design and small.Stainless steel table-board looks clean and beautiful.It can be used as long as equipped with gas or other civilian fuels.It is easy to use and test results exact.

 

II. Main technical specifications

1. Power supplyAC( 220±10% )V, 50Hz.

2. Total power consumption:≤650W;

3. Heating device(1) The furnace is silicon carbide material. Power is 600W.

              (2) The heating power is adjustable from 0 W to 600W.

4. Heating rate: Procedure A: (56)℃/min,

Procedure B:(11.5)℃/min.

Procedure C:(2.53.5)℃/min 

5. Stirring device(1)Stirring motor

                (2) Driving mode: flexible shaft

                (3) Shaft size: 8mm×40mm             

6. Stirring rate: Procedure A: (90120) RPM

Procedure B: (250±10) RPM

Procedure A: (90120) RPM

7. Stand oil cup(1)Internal diameter50.7mm50.8mm

               (2) Depth: 55.7mm56.0mm

              (3) Marking depth of oil testing capacity: 33.9mm34.3mm;

              (4) Oil test capacity: about 70ml;

8. Igniting device(1) Igniting source: gasor other civilian fuelsthe same below

9. Suitable environment

Ambient temperature1535

Relative humidity≤85%

10. Dimension340mm×330mm×380mm

11. Net weight9kg.